Quantcast
Industry Cortex

Document Brief

Protocol API...

PROFINET IO-Controller...

Hilscher Gesellschaft f r Systemautomation mbH www.hilscher.com...

DOC050901API13EN Revision 13 English 2010-12 Released Public...

Revision History Rev 0 1 2 3 Date 2005-09-02 2007-08-10 2007-10-15 2007-10-15 Name JK BM/RG BM BM/RG Revisions Created Extended section 1 Extended sections 5.6.3, 4.1, 5.5.4.2, 5.5.5.2 Added section 5.5.7, 5.5.7 Fixed problem in section 5.6.2. Additions in configuration section. PROFINET IO RT Controller version 2.0 4 2008-03-04 RG Review of technical data section. Firmware/ stack version 2.0.109 5 2008-05-03 BM/HH API-Change Added field ObjectUUID LocalIndex to packet defined in section 5.3.3.1 API-Change Made fields "usUserStructId" and "abAlarmData" optional in packet defined in section 5.6.3.1 Extended textual description in sections 5.6.3 and 5.4.1 Review of technical data section (now supporting up to 128 IO-Devices) Removed limitation "only 25 IO-Devices with cycle time 1ms" instead added a note that cycle-time, number of IO-Devices and amount of IO-data depend on each other Added remark about firmware changing a configured parameter to section 0 Added 2 new cases why SF-LED may flash (section 7) Firmware/stack version 2.1.56 Reference to netX Dual-Port Memory Interface Manual Revision 5. 6 2008-09-09 BM/RG/ET Firmware/ stack version V2.1.153 Registration/unregistration packet marked as obsolete. Changed sections 1.5.5 concerning diagnosis buffer and its restrictions Changed some error numbers to global error numbers Added a lot of new error numbers Some error corrections Reference to netX Dual-Port Memory Interface Manual Revision 6 7 2008-11-27 RG Firmware/ stack version V2.2.2. Reference to netX Dual-Port Memory Interface Manual Revision 7 Added section on task structure. 8 2009-04-16 RG Firmware/ stack version V 2.2.6. Reference to netX Dual-Port Memory Interface Manual Revision 7 Added some error message descriptions Maximum number of total cyclic input data respecively output data is now 5760 bytes each...

Reference to netX Dual-Port Memory Interface Manual Revision 9. Continued on next page...

PROFINET IO-Controller DOC050901API13EN Revision 13 English 2010-12 Released Public...

Hilscher, 2006-2010...

Date 2009-05-27...

Revisions Firmware/ stack version V 2.2.7. Added missing Limitation only API = 0 is supported Figure 9 Task Structure of the PROFINET IO Controller Stack updated...

2009-08-18...

Firmware/ stack version V2...

Document Keywords

PROFINET IO Controller (Protocol API) hcuk files manuals profinet io controller protocol api 13 en