Document Brief

See unit nameplate for manufacturer and address. 506380-01 11/2009...

KGA024, 030, 036, 048, 060, 072...

(2, 2-1/2, 3, 4, 5, and 6 Tons)...

KGA092, 102, 120, 150...

(7-1/2, 8-1/2, 10, and 12 Tons)...

KGA180, 210, 240, 300S...

(15, 17-1/2, 20, and 25 Tons)...

ROOFTOP UNITS...

KGA092 SHOWN...

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE...

Litho U.S.A. 2009...

FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage. D Do not try to light any appliance. D Extinguish any open flames. D Do not touch any electrical switch do not use any phone in your building. D Leave the building immediately. D Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. D If you cannot reach your gas supplier, call the fire department....

WHAT TO DO IF YOU SMELL GAS ...

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier....

P506380-01 ...

KGA024, 030, 036, 048, 060, 072, & 090 Parts Arrangement...

FILTERS (4)...

024, 030, 036, 048, 060 16 X 20 X 2" 072, 090 20 X 20 X 2"...

ECONOMIZER (OPTIONAL)...

EVAPORATOR COIL...

BLOWER MOTOR...

TB1 LOW VOLTAGE TERMINAL BLOCK...

CONDENSER FAN...

CONDENSER COIL CONDENSATE DRAIN...

COMBUSTION AIR INDUCER...

COMPRESSOR...

KGA092, 102, 120, & 150 PARTS Arrangement...

DISCONNECT / CIRCUIT BREAKER (FACTORY OR FIELD INSTALLED OPTION)...

CONDENSER FANS CONDENSER COIL...

COMPRESSORS FILTERS (FOUR - 20 X 25 X 2") CONDENSATE DRAIN...

COMBUSTION AIR INDUCER BURNERS...

506380-01 11/2009...

KGA180, 210, 240, 300 Parts Arrangement...

FILTERS (SIX - 24 X 24 X 2") ECONOMIZER DAMPERS (OPTIONAL)...

INDOOR COIL OUTDOOR FANS (3 FANS ON 180 & 210 UNITS)...

FILTER DRIERS...

CONDENSATE DRAIN...

OUTDOOR COILS (RIGHT COIL IS VERTICAL ON 180 & 210 UNITS)...

TB1 HEAT EXCHANGER GAS VALVE BURNERS COMBUSTION AIR INDUCER...

COMPRESSORS...

1 - Keep unit area clear and free of combustible materials, gasoline and other flammable vapors and liquids. 2 - Do not obstruct air flow to unit. Unit must receive an unobstructed flow of combustion and ventilating air....

Electric shock hazard. Can cause injury or death. Before attempting to perform any service or maintenance, turn the electric...

Document Keywords

Lennox KGA Commercial Units - 2 through 25 tons manuals kga commercial units through 25 tons